Fluidwell Explosion Proof Meter
CSA approved explosion proof for use in hazardous applications, the loop powered field meter displays engineering units connected in series with one 4-20 mA transmitter.
The meter is typically selected for use with an explosion proof transmitter within a hazardous area.
The windowed field enclosure is wall mounted for convenient viewing.
Tech Tip
For explosion proof level measurement and indication, package your meter with the EchoSafe XP ultrasonic transmitter. It's level made simple.
| Display type: | LCD, 5 1/2 digit |
| Display units: | Engineering |
| Decimal point: | 0, 1, 2 or 3 |
| Display output: | 0.001 to 99,999 |
| Display height: | Main: 1 (26 mm) Secondary: 0.3” (8 mm) |
| User interface: | Three push button |
| Sensor input: | (1) 4-20 mA transmitter |
| Loop power: | 10-30 VDC |
| Memory: | Non-volatile |
| Voltage drop: | 2.6 VDC @ 20 mA |
| Ambient temp.: | F: -40° to 176° C: -40° to 80° |
| Enclosure rating: | NEMA 4, 7 & 9 (IP66) |
| Enclosure mat'l.: | Aluminum |
| Window mat’l.: | Glass |
| Conduit entrance: | Dual, 3/4” NPT |
| Compliance: | CE, UL |
| EN61326, EN61010-1 | |
| Approvals: | Explosion proof CSA: Class I, Groups C, D; Class II, Groups E, F, G; Class III; T-code = T4 |
Other Level Sensor Products
Matrix of Level Sensor Products
Level Transmitter Application Success Stories